PART 1 GENERAL 1.01 Scope A. Furnish and install FABRITRAK(r) Wall System as manufactured by FABRITRAK(r) Systems, Inc. and as required by the Contract Documents. B. Related Work Specified Elsewhere 1. Preparation of smooth, flat and plum substrate. 2. Architectural Woodwork, Masonry, Doors and Frames, Hardware, Gypsum Drywall, plastering, Ceilings, Wall Covering, Painting and Electrical Work. 1.02 Standards The acoustical or tackable wall treatment system shall have a Fire Hazard Classification of Class 0-25 when tested in accordance with ASTM E-84. 1.03 Qualifications The installation work of this Section shall be performed by an authorized dealer, licensed by the manufacturer, and shall be a member of the Wall Upholstery Guild of America (W.U.G.A.) and shall be certified as such. 1.04 Quality Assurance A. The fabric shall be stretched tautly over the subsurface and the FABRITRAK(r) System framework without the use of glue. B. The fabric border shall be inserted completely into the clamping inlet jaws of the FABRITRAK(r) framework creating a clean crisp appearance devoid of raw edges or loose threads. C. The fabric shall be installed from the face side after framework is securely fastened to insure perfect horizontal and vertical grain alignment. D. The fabric pattern shall be matched and true, certain fabrics cannot be matched. E. The fabric shall be removable and replaceable for changeability and to provide access to the surface behind the fabric. F. The framework shall not "read through" the fabric. G. An interlining shall be installed beneath the face fabric in the event a translucent fabric has been specified. 1.05 Submittal A. Submit manufacturer's product specifications and such other data as may be required to show compliance with the Contract Documents. B. Submit in writing to the Owner, through the Architect, the manufacturer's dealer certification. C. Submit installation Dealer's five year Limited Warranty against defects in the FABRITRAK(r) materials and workmanship. D. Installation dealer shall submit a list with a minimum of five (5) comparable installations. 1.06 Product Handling A. Store all materials off the ground and protected from dirt and dust of construction operations. B. Handle materials in a manner that will protect them from damage and soiling. PART 2 PRODUCTS 2.01 Acoustical or Tackable Wall Treatment System A. The system shall consist of site installed and fabricated, concealed FABRITRAK(r) System as manufactured by FABRITRAK(r) Systems, Inc. For the authorized dealer in your area contact: Fabric Wallcraft, Inc. 31658 Rancho Viejo Rd. Ste. E San Juan Capistrano, CA 92675 800-615-0516 949-248-2899 bmoore@fabricwallcraft.com www.fabricwallcraft.com B. The System Components shall consist of the following: 1. Rigid vinyl framework with clamping jaws, one-piece section: (Select correct thickness below, eliminate others not used) 3/8", 1/2", 1", 2" thickness - fire retardant FABRITRAK(r) System. 2. The FABRITRAK(r) System is available with the following edge profiles. (Select the correct profile below, eliminate the others not used). RE (Radius), SE (Square), BE (Bevel), FE (Flat or Monolithic). 3. The FABRITRAK(r) System is available with the following sub-surfaces (underlay). (Select the correct sub-surface below, eliminate the others not used.) ACOUSTICAL: FABRI-FILL(tm) - 3/8", 1 /2" or 3 /4" thick compressible, F.R. polyester padding. FIBERGLASS & ACOUSTIC SOUND CONTROL BOARD - 3/8", 1/2", 1", 2" or custom thickness rigid or semi-rigid underlay. TACKABLE: 3/8", 1/2", 1", 2" thick, custom Compressed Fiberboard - fire retardant Matt Faced Fiberglass - fire retardant Plywood - fire retardant ACOUSTICAL AND TACKABLE Combination subsurface - fire retardant Part Tackable and Part Acoustic. As per elevations. 4. Fabric: Shall be approved by the Installation Dealer as to suitability. The Architect (for the Owner) shall submit the following information concerning the fabric to the dealer. a. Fabric Manufacturer b. Width of Fabric c. Contents d. Style Number e. Color f. Flame Retardant g. Sample of fabric (at least 12" x 12") for approval by Installation Company. PART 3 EXECUTION 3.01 Existing Conditions A. Examine the condition of the substrate and the conditions under which the work of the Section is to be performed. Notify the Contractor in writing or any unsatisfactory conditions. Do not proceed with the work until unsatisfactory conditions have been corrected in a manner satisfactory to the installer. B. Do not install acoustical wall panel fabric in any space until: 1. The space is enclosed and is weather tight. 2. All wet work has been completed and is dry. 3. Painting is completed and wall base and floor covering installed. 4. All adjacent and related work of other trades has been completed including, in part Architectural Woodwork, Masonry, Doors and Frames, Hardware, Gypsum Drywall, Plastering, Wall Covering, Painting, Ceiling Grid and Electrical Work. 5. Ambient temperature and humidity are continuously maintained at values indicated for final acceptance of the building or occupancy of the space 3.02 Installation A. Field measure each wall area, which is to receive the acoustical or tackable treatment to establish the exact layout of the units as shown on elevations. B. Apply the FABRITRAK(r) framework in the areas to receive the acoustical wall treatment as shown on the drawings. Secure the framework with suitable mastic and special, heavy duty; one-inch diverging staples located not more than 2" on center. Other fasteners may be used as required for specific substrates, providing they are strict accordance with the manufacturer's printed instructions and comply with governing regulations and fire resistance rating requirements specified. C. Install the FABRITRAK(r) framework plumb and straight, flush in proper alignment. D. Install the sub-surface material, continuous and flush, to the shoulder of the track. E. Cut the fabric from each roll marking and maintaining sequence of drops and matching direction of weave for sequential and uniform installation. F. Install the fabric from the face side after the framework is securely fastened to insure perfect horizontal and vertical grain alignment. G. The fabric shall be stretched tautly, evenly and smoothly and be free of defects and flaws. H. No stapling or gluing of fabric to core or channels will be permitted. I. Penetrations through the face of fabric of any kind (i.e. staples, nails, etc.) will be prohibited. J. Prewrapped, prefabricated, or wood ground systems do not meet the intent of this specification. K. Installation shall be timely and installers shall be courteous and cooperate with other trades. 3.03 Cleaning and Protection A. Clean exposed surfaces of acoustical wall panels. Trim and remove all loose threads. B. Remove surplus materials, rubbish and debris resulting from the FABRITRAK(r) installation and leave areas of installation in a neat, clean condition. C. If site conditions require, cover fabric panels with vinyl drop cloths. END OF SECTION For More Information Contact: Bart Moore Fabric Wallcraft, Inc. 1-800-615-0516 949-248-2899fax bmoore@fabricwallcraft.com www.fabricwallcraft.com